SonicWall
Connect SonicWall to collect configuration, access and security evidence for AssurIQ controls.
Updated Aug 18, 2026Product 2026.96 minMSP operator, Internal IT
Prerequisites
- SonicOS management API enabled
- Read-only Auditor account
- Vendor
- SonicWall
- Category
- security
- Connector
- Open Integrations
Purpose
The SonicWall connector reads firmware, security service and firewall rule state from SonicOS appliances to assess management exposure and patch currency for gateway devices.
Requirements
- SonicOS 7.x with management API access enabled
- A read-only administrator account
- SNMP enabled for interface and system metrics, or API-only polling where supported
Permissions
- Administrator with the Auditor/Read-Only privilege level
- API key or credential scoped to that account for HTTPS management API polling
Setup
- 1Enable the management APIUnder Manage > Appliance > Base Settings, enable the SonicOS API.
- 2Create a read-only administratorCreate an administrator account assigned the Auditor role.
- 3Restrict management accessLimit API/management access to the AssurIQ collector's source address.
- 4Add the credential to AssurIQStore the account credential in the Credential Vault and add the device under Integrations.
- 5Confirm collectionVerify firmware, license and rule evidence populate on the next cycle.
Verification
- Device appears in Attack Surface with current firmware version
- Security service (Gateway AV, IPS) license status is visible
- Firewall rule count and NAT policy summary populate in evidence
Data collected
- Firmware version and security service license status
- Firewall access rules and NAT policy summary
- Interface configuration and internet-facing status
- System resource and session metrics
Security model
The Auditor role is read-only across the SonicOS management interface and cannot alter configuration. Management API access is restricted to the collector's source address and travels over HTTPS.
Common errors
| Code | Title | Fix |
|---|---|---|
| AIQ-CRD-001 | Credentials failing | The Auditor account password rotated; update the Credential Vault entry. |
- AIQ-CRD-001Credentials failingStored credentials were rejected by one or more targets.
Troubleshooting
- If firmware shows out of date, confirm the appliance has synced with MySonicWall for advisory metadata.
- If rules are missing, confirm the Auditor role has visibility into the relevant security zone.
Disconnect
- Remove the device from AssurIQ Integrations.
- Delete or disable the Auditor administrator account on the appliance.
Was this helpful?